"Promoting the Science of Sterilisation"

Batch Monitoring System is used for routine monitoring in pre vacuum sterilisation processes in each cycle, batch/load to detect insufficient air removal, leakages and non condensable gases in the steam that would be critical in MIS instruments. The gke Batch Monitoring System is designed to monitor steam penetration at the most difficult positions inside the sterilisation load. This information cannot be achieved by measuring the physical data - Temperature, Time and Pressure.

Bowie Dick Simulation Test The gke Bowie Dick Test is used as a functionality check of steam sterilisers to prove air removal and steam penetration according to EN 285 and EN 554. The gke Bowie Dick Simulation Test can be used as an alternative for the standard cotton package and additionally simulate hollow devices which require more demanding air removal and steam penetration conditions in comparison to the porous cotton or commercially produced packs to 7kg. The European Standard EN 285 (2006+A1) March 2008 Steam sterilizers - Large sterilizers has been updated since it has been proven that the porous BD-test pack cannot guarantee the steam penetration and therefore sterilisation of complex hollow devices. The BD-test does not replace the Batch Monitoring System during sterilisation.

Class 6 Indicators Indicators for pack monitoring are used in steam sterilisation processes, to monitor the successful sterilisation inside of packs. Pack monitoring indicators should only be used if solid and porous goods are sterilised. All pack monitoring indicators only provide sterility information on top of the surface of an instrument at the point they are located. To monitor hollow goods, eg tubes and minimal invasive surgery (MIS) instruments, requires a PCD including a Class B/Class 2 Indicator in accordance with EN 867-5

Patient Tracing For load/batch Patient-Related Documentation and Tracing of the Sterilistation Process. The gke Patient Tracing Systems consist of 3 components (3 line Hand Labelling Applicator Gun, Piggyback Label with steam process indicator, and Patient Documentation (Sterliiser Log Books & Patient Record Notes)

Office Based Practice Original and new Batch Monitoring System for hollow monitoring of handpieces. Process Challenge Device also known as Helix. For B Type Pre Vacuum Benchtop Sterilisers.

Container Seals This product is used to seal instrument containers to prevent accidental use of the content, if the container has been tampered with or opened by mistake.

Dr Weigert neodisher - Cleaning & Disinfection of Medical Devices Reproducability and validated cleaning and disinfection processes are the pre-requisites for safe and hygienic conditions.

e-line Packaging Solutions Packaging solutions for medical devices.